Tennessee, 100 tornadoes reported this week and ef1 tornado touching down in north carolina, ginger is tracking it all including a new line of storms on the move as seasons collide with record heat in the south in the free sweeping east. Overnight, new clashes on College Campuses from washington, d. C. , to arizona. Amid growing fallout from President Bidens warning to israel. Stormy daniels, defiant on the stand, sparring with Donald Trumps lawyers over their alleged encounter in a hotel suite. Now who testifies next . Body camera footage released of the u. S. Air man fatally shot at his own home by a sheriff deputy. Sheriffs office, open the door a speak of the investigation as his family demands answers. Shark attack survivor. Speak of the worst thing i thought was i dont want to be eaten by ten sharks. How this florida man fell into shark infested waters and got out alive. Arrested in paradise, after security on the world caribbean cruise found ammunition in one mans back. All i wa
The 31 notification appeal, with is what we have here and were asking for instruction from you to my client to work with the department, to make the necessary corrections. Good afternoon. I am a permit expeditor working with the city of San Francisco and a contractor that dealt with this problem not the problem, but the inconsistency with the contractor and told them what was going on. Let me show you a couple of pictures of the light well. This is a light well, which shows the Property Line of the next door neighbor, there are two windows here, one window east and west for a bedroom. This green you see is the frame for duct inside this shaft. And the other side of that if you look at the other side, you can see that is the kitchen window. This is one bedroom. This is the other bedroom of its not blocked. I told the contractor to stop building this wall. Its a huge, humongous wall they built around for protection and i advised them not to continue until i directed them what to do. Base
Shaft. They are penetrating what they call a onehour wall, with a positive air make up for the exhaust fan for the hood. That is a rated wall and they need a fire damper there, in case there is a fire in the system. There is also an issue about penetrating. There is something block the overhead. I think the shade. The way its folded. I dont know what the problem is. This is the penetration through this onehour wall. Its a tradesmen is that better . Its a tradesman exit. They call it a tradesman, but its a required exit from the rear yard and if you are going to penetrate that with an air intake, you have to have a fire smoke damper there, which is what the Fire Department would have caught. They also have a penetration from the restaurant into the entrance into the building. Which would have required a fire smoke damper and more or a more important issue, a fundamental issue, they failed to get a permit for change in use from the previous use to a less than 50 restaurant thank you. And
Good evening madame chair lady and good evening members of the board. My name is gus and even as you look at, this we have a lot of contradictions that are occur. Now we only came across these citations this evening, at least i did and we had basically no time to respond to them. To make matters worse, you have a citation dated on the 3rd of december. You have another here dated the 4th of december. They are diametrically different. This one is talking about the violation. And this one is talking about a correction notice. And there is much difference between them. And the violation or the citation that mr. Duffy is aware of is the one that is asking for correction. This is the one that we got from here. We just got this a few minutes ago. While mr. Boskvich was talking. The issue is whether or not an installation or addition of a hood requires this notification. Yes, the Zoning Administrator and mind you the Zoning Administrator has authority to make interpretations on the zoning code
And there is much difference between them. And the violation or the citation that mr. Duffy is aware of is the one that is asking for correction. This is the one that we got from here. We just got this a few minutes ago. While mr. Boskvich was talking. The issue is whether or not an installation or addition of a hood requires this notification. Yes, the Zoning Administrator and mind you the Zoning Administrator has authority to make interpretations on the zoning code, as far back as 1996 has interpreted level 3 notification not to require for mechanical equipment additions. What level 3 is what 312 is to commercial or neighborhoodcommercial users. Basically the Zoning Administrator has seen it fit to be consistent and make the same interpretation with this particular project. Now what we have seen here is first of all, we are disputing that it needed any 312 notification on the current planning code. Basically these people would like you to come and address the issue of Code Amendment